User`s manual
External Modem User's Manual
40
CONNECT 115200 24 x x x x Connection established at 115200 bps
CONNECT 1200TX/75RX 25 x x x x V.23 established:transmit at 75 bps, receive at
1200 bps
CONNECT 75TX/1200RX 26 x x x x V.23 established:transmit at 1200 bps, receive
at 75 bps
CONNECT BELL 300 28 x x x x Connection established at Bell 300 bps
CONNECT V21 29 x x x x Connection established at V.21 300 bps
( Display DCE speeds by ATW0 and ATW2 )
CONNECT 16800 15 x x x x Connection established at 16800 bps
CONNECT 19200 16 x x x x Connection established at 19200 bps
CONNECT 21600 17 x x x x Connection established at 21600 bps
CONNECT 24000 21 x x x x Connection established at 24000 bps
CONNECT 26400 30 x x x x Connection established at 26400 bps
CONNECT 28800 31 x x x x Connection established at 28800 bps
CONNECT 31200 32 x x x x Connection established at 31200 bps
CONNECT 33600 33 x x x x Connection established at 33600 bps
(V.90 mode)
CONNECT 28000 34 x x x x Connection established at 28000 bps
CONNECT 29333 35 x x x x Connection established at 29333 bps
CONNECT 30666 36 x x x x Connection established at 30666 bps
CONNECT 32000 37 x x x x Connection established at 32000 bps
CONNECT 33333 38 x x x x Connection established at 33333 bps
CONNECT 34666 39 x x x x Connection established at 34666 bps
CONNECT 36000 40 x x x x Connection established at 36000 bps
CONNECT 37333 41 x x x x Connection established at 37333 bps
CONNECT 38666 42 x x x x Connection established at 38666 bps
CONNECT 40000 43 x x x x Connection established at 40000 bps
CONNECT 41333 44 x x x x Connection established at 41333 bps
CONNECT 42666 45 x x x x Connection established at 42666 bps
CONNECT 44000 46 x x x x Connection established at 44000 bps
CONNECT 45333 47 x x x x Connection established at 45333 bps
CONNECT 46666 48 x x x x Connection established at 46666 bps
CONNECT 48000 49 x x x x Connection established at 48000 bps
CONNECT 49333 50 x x x x Connection established at 49333 bps
CONNECT 50666 51 x x x x Connection established at 50666 bps
CONNECT 52000 52 x x x x Connection established at 52000 bps
CONNECT 53333 53 x x x x Connection established at 53333 bps
CONNECT 54666 54 x x x x Connection established at 54666 bps
CONNECT 56000 55 x x x x Connection established at 56000 bps
6.3 Application Examples
6.3.1 Dialing a Remote Modem
Command line: ATDP9WT002, (886)-7128423<CR>
This command line instruct the modem to dial a remote modem through a PBX. The modem
first use pulse dialing to dial 9 (the access code of the PBX), wait for outside dial tone, and
then use touch tone dialing to dial 002 once a one-second continuous dial tone is detected
within 30 seconds, pause for 2 seconds (if S8=2) and then dial 8867128423.
6.3.2 Dialing a Stored Number
Command line: AT&Z2=T03,709394<CR>
Command line: ATDS=2<CR>
The first command line store the dial string T03, 709394 to the 3rd location in NVRAM.
Afterwards you can use the second command line to dial this stored number. The dial string
T03, 709394 will appear on the screen to indicate the number being dialed.