User's Manual
4 EKAHAU T301-A USER GUIDE
Activation you see the MAC address of the tag appears on the Ekahau
Positioning Engine list of tags.
The tag will now automatically wake up scan and send results to
Ekahau Positioning Engine using the configured wakeup interval.
On scan, association to the network and sending results the lower
LED lights red and the upper LED blinks green twice.
2.3 Button scan
The tag can also be commanded to scan by pressing the blue or white
button. After button press the tag will scan immediately and send the
results to Ekahau Positioning Engine. The LEDs will indicate the scan
success or failure similarly as in the scan activated by the wakeup
interval.
2.4 Resetting to factory settings
The tag can be reset to factory setting by pressing using a button
sequence or by opening the back cover and removing the batteries. To
reset the tag using buttons using button sequence do the following:
1. Press the White button for 2 seconds
2. When the lower LED flashed orange press down the blue button
immediately.
3. After 2 seconds the lower LED flashes orange.
4. The tag has now been reset to factory settings. The tag is in reset
mode when it does not execute button scan as defined in section
2.3.
3 TECHNICAL SPECIFICATIONS
3.1 General
y Outside Dimensions (mm): 45 x 55 x 19
y Weight: 1.7 oz / 48 g with batteries