User's Guide
Table Of Contents
- Table of Contents
- Chapter 1. Introduction
- Chapter 2. Initial Activation of the Tag
- Chapter 3. Configuration After Initial Activation
- Chapter 4. Tag Operation
- 4.1. Button Activated Location Update and Maintenance Call
- 4.2. Safety Switch Activated Location Update
- 4.3. Working with the Display
- 4.4. Load Balance
- 4.5. Smart Roaming
- 4.6. Resetting to Factory Settings
- 4.7. Firmware Update
- 4.8. Optimizing Battery Life
- 4.9. Turning off the B4 Tag
- 4.10. Charging the B4 tag
- Chapter 5. Technical Specifications
- Chapter 6. Certifications
- Chapter 7. Limited Warranty
Values (Default underlined)DescriptionSetting
IP AddressSets the ERC IP AddressIP Address
Port numberPort number of location protocol port
of ERC
Location update Port (UDP)
Port numberPort number of maintenance pro-
tocol port of EPE
Maintenance port (UDP)
General
Free textName for the configuration setName
Free textDescription for the configuration setDescription
Channels
1- 11; 12 (EU); 13 (EU); 14 (Japan)Sets the channels scanned during
a location scan
Scan Channels
Periodic Location Update and Maintenance
Enabled; DisabledEnables or disables the periodic
location update
Periodic Location Update
The interval in Seconds, Minutes,
Hours or Days
Sets the interval for the periodic
location update
Location Update Interval
Enabled; DisabledEnables or disables the periodic
maintenance calls
Periodic Maintenance
The interval in Seconds, Minutes,
Hours or Days
The interval of the periodic mainten-
ance calls in seconds
Maintenance Interval
Sensors
Disabled
Profile 1 (in motion for 8s)
Profile 2 (in motion for 4s)
Profile 3 (in motion for 2s)
Profile 4 (in motion for 1s)
Enables or disables motion sensorsMotion Sensor
In-motion and after motion; After
motion
Sets whether location updates are
sent periodically during the motion
or just when the motion starts and
after the movement has ended
Motion Update Method
5s; 10s; 30s; 1min; 2min; 5minSets the interval for motion updatesMotion Update Interval
Enabled; DisabledEnables or disables stagnant sens-
ing
Motion Stagnant Event
The threshold in Seconds, Minutes,
Hours or Days
Sets how long the tag has to remain
stagnant to produce a stagnant
event
Motion Stagnant Treshold
18
Chapter 3. Configuration After Initial
Activation