3 Wiring
This chapter describes the wiring setup necessary for installing the DFGT in a decorative fireplace.
3.1 Overview connectors
In Figure 2 is illustrated which connectors are accessible from outside the housing of the controller PCB.
Figure 2. DFGT connectors accessible
3.1.1 Description connections
The connectors shown in Figure 2 are described below.
Connector
Function
Description
X6
Provides:
Configurable relay output
Modulation coil output
ESYS supply output
Power supply input
Relay: Output which can be configured for output
functionality such as boost or light. See 0.
Coil: Connect to modulation coil on ESYS
ESYS: Connect to power supply of ESYS
Power supply: Connect to mains
X5
Provides Triac outputs
Triac 1 & 2: Outputs which can be configured for output
functionality such as boost or light. See 0.
JP1
Sensor and communication
connections
I/O 1 to 4: Inputs and outputs which can be configured for
input functionality. See Appendix A.
I2C: Reserved for future use
ESYS-RX/TX: Connection for communication with ESYS