Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 58 of 59
Tag
Index & Name
Min
Max
Step
Default
Unit
Remarks
54
35. Boost fan user on/off allowed
0
1
1
1
-
0 – User is not allowed to
turn the boost fan on or
off.
1 – User is allowed to
control the boost fan
independent from the
burner state
When this setting is ‘0’
and the boost fan starts
running, it runs on the
lowest speed specified in
the mapping table (first
entry)
When this setting is ‘0’,
the boost user
configuration is ignored
42100
36. Light wave interval
0
240
1
15
s
See 5.7.1
42101
37. Light wave selection
0
2
1
0
-
0 – Wave for the light
disabled
1 – Follow burner wave
pattern (in sync with the
burner)
2 – Follow light wave pattern
42200
38. Wave user configuration
0
4
1
0
-
0 – Not available
1 – Switch off at ignition
2 – Switch on at ignition
3 – Apply last state at
ignition
4 – Available, do nothing
at ignition
42201
39. Light user configuration
0
4
1
0
-
0 – Not available
1 – Switch off at ignition
2 – Switch on at ignition
3 – Apply last state at
ignition
4 – Available, do nothing
at ignition