Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 57 of 59
Tag
Index & Name
Min
Max
Step
Default
Unit
Remarks
42001
19. Input 2 function
0
19
1
0
-
See Appendix A
42002
20. Input 3 function
0
19
1
0
-
See Appendix A
42003
21. Input 4 function
0
19
1
0
-
See Appendix A
42010
22. Output Triac 1 function
0
10
1
0
-
See Appendix B
42011
23. Output Triac 2 function
0
10
1
0
-
See Appendix B
42012
24. Output Relay function
0
10
1
0
-
See Appendix B
42013
25. Output ESYS function
0
10
1
0
-
See Appendix B
42020
26. Wave Interval
0
240
1
15
s
42021
27. Min Wave height
0
100
1
5
%
60050
28. Daylight saving
1
4
1
4
-
1 – None
4 - Europe
60051
29. Time-zone offset
-
840
840
30
60
min
Time-zone offset to UTC in
minutes
60110
30. NVM Store Directly
0
1
1
0
-
NVM storage is delayed for
2 seconds each time a write
operation is requested (up to
30 seconds total). Changing
this setting to 1 triggers the
NVM storage to resume
immediately. After that this
setting can be polled, as it
will return to 0 once the
NVM storage process is
completed. Mainly used for
production tool
50
31. Boost fan run on time
0
600
1
0
s
Time the boost fan stays on
after turning it off
51
32. Boost fan available levels
1
15
1
1
-
Number of available levels
that are selectable by the
DFRC
52
33. Light available levels
1
15
1
1
-
Number of available levels
that are selectable by the
DFRC
53
34. Boost fan start delay
0
600
1
0
s
Time after ignition when the
boost fan can be controlled