Appendix C Settings & factory defaults
This appendix describes the defaults settings of the DFGT
Tag
Index & Name
Min
Max
Step
Default
Unit
Remarks
1
0. Minimum current
45
250
1
45
mA
The current that is
needed to set the gas
valve in the position
according to the required
minimum flame height.
2
1. Maximum current
45
250
1
250
mA
The current that is
needed to set the gas
valve in the position
according to the required
maximum flame height.
3
2. Start current main gas valve
45
250
1
215
mA
The current that is
needed to set the gas
valve in the ignition
position. This current is
not limited by the
minimum and maximum
flame height currents
4
3. Start current second gas valve
45
250
1
215
mA
The current that is
needed to set the gas
valve in the ignition
position for the second
burner. This current is not
limited by the minimum
and maximum flame
height currents
5
4. Start time main gas valve
0
240
1
30
s
The time it takes to ignite
the main burner.
6
5. Start time second gas valve
0
240
1
10
s
The time it takes to ignite
the second burner.
7
6. Max Time Ignite State
60
240
1
240
s
After ignition, a flame must
be detected within the set
time. If not, the gas valve
will be closed and there will
be an error indication on
both the user interface of the
DFGT and the Remote
Control of the decorative
fire. The user has to ignite
the decorative fire again.
The value must be chosen
in such a way that the time
is sufficient for fireplace to
run a complete start cyclus