Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 54 of 59
Appendix B Output configuration options
This appendix describes configurable output functions available on connector X5 (Triacs), X6 (relay) and separate
output on ESYS.
Function
Triac1
Triac2
Relay
Esys output
(1)
Description
0) Not Used
x
x
x
x
Output has no function (default)
1) Second burner
x
x
x
x
On/Off signal
2) Boost fan
x
x
x
x
Switched On/Off by user
3) Boost fan modulated
x
x
Modulating signal, controlled by user
4) Light
x
x
x
x
Switched On/Off by user
5) Light modulated
x
x
Modulating signal, controlled by user
6) Burner release
x
x
x
x
Active in case burner is (almost) on
7) Main burner release
x
x
x
x
Active in case the main burner is (almost) on
8) Error
x
x
x
x
Active in case there is an error active
9) Hold
x
x
x
x
Active in case the flame height cannot be
controlled (same as sent to DFRC)
10) Reset Allowed
x
x
x
x
Active when fault active and fault can be reset
(same as sent to DFRC)
(1)
Boost Fan output Esys (triac)