Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 50 of 59
13 Safety issues
To reach the highest possible safety level, the following must be taken into consideration:
1. always apply to safety regulations
2. always apply to local regulations
3. don’t expose the DFGT to a too high temperature
4. take care of a good communication between the Remote Control and the DFGT
5. take care of a good air ventilation
13.1 24-hour operation (only DFGT-SP)
Due to safety regulations, the CVI is not allowed to release the gas valve for a continuous time longer than 24
hours. To achieve this, the DFGT switches the CVI off (indicated by A in figures) in case:
1. The main burner has been continuously on for 24 hours (see Figure 21)
2. The pilot flame has been continuously on for 24 hours (the on/off state of the main burner is of no importance,
see Figure 22).
3. The pilot flame is on, but the main burner has been switched off six hours ago (see Figure 23)
Figure 23: Main burner continuously on for 24 hours
Figure 24: Pilot flame continuously on for 24 hours