Quick Start Guide

Quick Start Guide DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 Draft Page 45 of 59
Tag
Data
Unit
Description
E00E
Actual flame height
%
Flame height without limiters
E00F
Burner status
-
0: Off
1: Igniting pilot
2: Igniting main
3: Pilot on
4: Waiting modulation level
5: Main burner on
6: Secondary burner on
7: Post purge
E010
Requested current
mA
E011
Valve current
mA
E004
ESYS error
-
E003
Ionization current
-
Raw measured current from ESYS
E001
Input potentiometer
Ω
E000
Input 0 10v
V
30C9
Input room temperature
°C
1290
Input outside temperature
°C
2309
Room setpoint
°C
FA80
Raw analog input 0
-
FA81
Raw analog input 1
-
FA82
Raw analog input 2
-
FA83
Raw analog input 3
-
FA84
Internal temperature
°C
Resolution and accuracy are less 4K
313E
UTC time
s
In seconds since 1-1-1970
If below 2018 it is counting since power-
up, at power it starts at 1-1-2000
E012
Time kind
-
0: Not valid (power-up)
1: Valid UTC time
E013
Daylight saving
-
0: Unknown
1: Wintertime
2: Summertime
2E10
Person present
-
0: No person present
1: Person present