Quick Start Guide

Quick Start Guide DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 Draft Page 44 of 59
12 Diagnostics
To check the overall operating of the DFGT you can use the following aids:
1. Operating counters (readable via service tool, DFRC-SE, BRDG and BLE device)
2. Fault codes (visible on Remote control and readable via service tool DRFC-SE, BRDG and BLE device)
3. Fault counters (readable via service tool DFRC-SE, BRDG and BLE device)
4. Fault history (readable via service tool DFRC-SE, BRDG and BLE device)
12.1 Operating Counters / operating data
The operating counters give information about the general use of the DFGT. The maximum value of each counter
is 65535. The actual value of the operating counters can be read by the service tool (DFRC-SE), BRDG and BLE
device. Table 5 gives an overview of the available counters and their specific function and contains also operating
data.
Table 5: Operation Counters
Tag
Index
Function
Counter Type
F000
1
Pilot
Operation Hours
F001
2
Main Burner
Operation Hours
F002
3
Second Burner
Operation Hours
F003
4
Light
Operation Hours
F004
5
Boost fan
Operation Hours
F005
6
Pilot
Operation Starts
F006
7
Main Burner
Operation Starts
F007
8
Second Burner
Operation Starts
F008
9
Light
Operation Starts
F009
10
Boost Fan
Operation Starts
Table 6 describes operating data of the DFGT, also referred to as actual data.
Table 6: Actual Data
Tag
Data
Unit
Description
E00A
Request pilot
-
0: Request pilot off
1: Request pilot on
E00B
Request main burner
-
0: Request main off
1: Request main on
E00C
Request secondary burner
-
0: Request secondary off
1: Request secondary on
E00D
Flame height
%