When the internal temperature of the unit rises above 60°C the unit goes to Fault mode.
Only when the internal temperature of the unit drops below 40°C the unit can leave Fault mode by resetting the
fault.
10.3 Ignition Cable
To avoid disturbance of the RF communication, it is not allowed to place the ignition cable in the vicinity of the
DFGT (see figure 17).
Figure 19: Minimum distance between ignition cable and DFGT
Take the following actions to prevent EMC problems:
1. Keep the ignition cable as short as possible.
2. Prevent ground loops.
3. Make an earth connection as close as possible to the ignition rod.
4. Connect this earth connection directly with the earth connection of the Burner Control by an electrical wire.
5. Also connect this earth connection directly with the earth connection of the Decorative Fire by an electrical wire.
A free space around the DFGT of at least 3 cm is recommended (see Figure 16).
The ambient temperature of the DFGT and the Burner Control may not exceed 60°C.