Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 32 of 59
6 Wave
The DFGT can vary the flame height according to a wave pattern. The wave pattern can be configured with the
Production Tool.
6.1 Wave features
The wave consists of a pattern of maximum 20 intervals each with its own flame height. This pattern is constantly
repeated. The pattern starts with the flame height of the first interval. When the interval time expires, the flame
height of the next interval is set. When all intervals are handled or the flame height of the next interval equals zero,
the pattern is repeated.
The following settings are related:
Tag
Name
Min
Max
Step
Default
Unit
Remarks
32
Wave available
0
1
1
0
-
42020
Wave interval
0
240
1
15
s
This is the interval for which
the next entry of the burner
wave table is applied.
This is also applied to the
light when configured to
follow the burner wave
42021
Min wave height
0
100
1
5
%
For the burner this is the
minimal flame height for the
wave.
This is also applied to the
light when configured to
follow the burner wave
42200
Wave user configuration
0
4
1
0
-
0 – Not available
1 - Switch off at ignition
2 - Switch on at ignition
3 - Apply last state at
ignition
4 - Available, do nothing at
ignition
6.2 Wave controls
The amplitude of the wave for the burner(s) depends on:
1. The selected user flame height
2. The factory setting minimum wave flame height
Some examples:
Blue bars : Wave table, equal to pattern indices values
Red bars : Demand 90% and activating wave
Green bars : Demand 50% and activating wave