Quick Start Guide

Quick Start Guide DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 Draft Page 24 of 59
Figure 15 : Relation between 0 10 volt input and load demand
Table 3: Table 1: 0 10 volt mapping table
Voltage
input (V)
Burner request
Only main burner
available
Flame height (%)
Only main burner
available
Burner request
Second burner available
Flame height (%)
Second burner available
0.0
No burner request
0
No burner request
0
0.5
0
0
1.0
Only main burner
0
Only main burner
0
1.5
5.5
11.5
2.0
11.0
23.0
2.5
16.5
34.5
3.0
22.0
46.5
3.5
27.5
58.0
4.0
33.0
69.5
4.5
38.5
81.0
5.0
44.0
93.0
5.3
47.5
100.0
5.5
50.0
Hysteresis
0
10
20
30
40
50
60
70
80
90
100
0 1.5 2.1 2.7 3.3 3.9 4.5 5.1 5.7 6.3 6.9 7.5 8.1 8.7 9.3 9.9
F
l
a
m
e
h
e
i
g
h
t
(
%
)
Voltage input (V)
one burner
burner 1 ON
burner 1 & 2 ON