Quick Start Guide

Quick Start Guide DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 Draft Page 20 of 59
Tag
Name
Min
Max
Step
Default
Unit
Remarks
42021
Min wave height
0
100
1
5
%
For the burner this is the
minimal flame height for the
wave.
This is also applied to the light
when configured to follow the
burner wave
42101
Light wave selection
0
2
1
0
-
0 Wave for the light disabled
1 Follow burner wave
pattern (in sync with the
burner)
2 Follow light wave pattern
60050
Daylight saving
1
4
1
4
-
1 None
4 - Europe
60051
Time-zone offset
-840
840
30
60
min
Time-zone offset to UTC in
minutes
4.2.2 LED
The PCB itself contains the so-called internal LED. An external LED can be connected to a connector (JP1) on the
PCB. The external LED operates the same as the internal LED, with one exception, namely if the push button is
pressed, the external LED will be off.
The actual status of the DFGT is indicated by the blinking rate of the LED (see table 2). To visualize the blinking
rate more clearly, the same blinking rate is represented by a blinking pattern (see figure 12)
Table 2: Relation between blinking rate and DFGT status
LED indication
Pattern
Status
On Time (ms)
Off Time (ms)
0
Continuous
A
Power not connected or hardware failure
Continuous
0
B
Not configured correctly
100
4900
C
Normal operation (ESYS OFF)
1000
4000
D
Normal operation (ESYS ON)
100
100
E
No communication with ESYS
1000
1000
F
Ignition control failure
800
200
G
No RF communication
100
1900
H
RF Binding mode
100
900
I
Internal failure, like max temperature reached