Quick Start Guide
Quick Start Guide – DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 – Draft Page 19 of 59
The push button has several functions, dependent on the duration of the button press, the state of the Burner
Control and the used application (see table 1)
Table 1: Operation of push button related to the duration of the pressed time
Duration
Burner control
state
Application
Action
< 1s (short press)
Fault
-
Reset of burner control
< 1s (short press
and release button)
No fault
DBI
Off -> On 100% load -> On 0% load ->
Off
< 1s (short press
and release button)
No fault
DBI + second burner
Off -> On 100% load second on -> On
100% load second off -> On 0% load -
> Off
< 1s (short press
and release button)
No fault
SP
Off -> On 100% load -> On 0% load ->
Pilot on -> Off
< 1s (short press
and release button)
No fault
SP + second burner
Off -> On 100% load second on -> On
100% load second off -> On 0% load -
> Pilot on -> Off
5 -10s
and release button
-
-
RF or BLE binding mode
>10s and release
button
-
-
Factory reset
Hold button during
power-up
Enable Ramses RF communication.
This is not stored in NVM.
4.2.1.1 Factory reset
The following information will be cleared via factory reset:
BLE bonding information
RF binding list
Time schedule switch points
Roomtemperature setpoint
The following settings will be set to factory default:
Wave pattern for flame height
Wave pattern for the light
Tag
Name
Min
Max
Step
Default
Unit
Remarks
55
Person present timeout
time
0
480
1
30
min
Time before person present
control becomes active