3.4 Second burner
Tag
Name
Min
Max
Step
Default
Unit
Remarks
20
Secondary burner
available
0
1
1
0
-
For second burner available set to ‘1’
23
Enable secondary
burner on when
main burner on
0
2
1
0
-
0 – On ignition only main is switched
on
1 – On ignition main and second are
switch on in sequence
2 – On ignition main and second are
ignited (even if second is not switched
on)
A fireplace can have a second burner next to the main burner.
The second burner can be an extension to the main burner or be placed parallel to create more flames. For this
there are some configuration options:
1. Normally only the main burner is ignited when the user ignites the fireplace using the remote or APP (set
setting tag 23 to 0)
2. Normally the main and afterwards the second burner is ignited when the user ignites the fireplace (set
setting tag 23 to 1). The delay is set with setting tag 6, Start time second gas valve.
3. Normally the main and second burner are ignited simultaneously when the fireplace is ignited. (set setting
tag 23 to 2)