Figure 10: Delay time between burner(s) switching off and a new ignition
The flame height can be adjusted during normal use. The adjustment of the flame is limited between a minimum
and maximum value. These minimum and maximum flame height values are set at the factory (see settings). The
relation between the pressure and the modulation current of the Moduplus White is shown in the figure below.
Figure 11: Modulation characteristics of Moduplus White
Notes: The pressure range is 1..37 mbar. Position of the Moduplus is sideward. Modulation current 0..250mA,
white coil Inlet pressure 60 mbar. Outlet orifice diameter 4.3 mm
Tag
Name
1
Minimum current
2
Maximum current
3
Start current main gas valve
4
Start current second gas valve
5
Start time main gas valve
6
Start time second gas valve
8
Post purge time