Quick Start Guide

Quick Start Guide DFGT-03MCXXX
Copyright © 2021 Airios. All rights reserved.
Airios Confidential and Proprietary Revision 15 Draft Page 13 of 59
Tag
Name
Min
Max
Step
Default
Unit
Remarks
8
Post purge time
0
255
1
2
s
The delay time between
the switching off and the
re-ignition of the
decorative fire. The time
must be choosen in such a
way that the time is
sufficiënt for the decorative
fire to cool down enough.
22
Open closed
0
255
1
255
-
0 Open fireplace
1 Closed fireplace
255 Not configured
Should be set to 0 or 1
after product is configured
(settings above)
3.3.2 Ignition type
The DFGT supports two types of ignitions with the ESYS module. These are described in the following paragraphs.
3.3.2.1 Direct Burner Ignition (DBI)
With direct burner ignition, no pilot flame is available. The main burner can be ignited directly. After a configurable
time, the second burner can be ignited. The DFGT offers an option to automatically ignite the second burner when
the main burner was ignited, and time has elapsed.
This functionality is configurable through the following settings:
Tag
Name
Min
Max
Step
Default
Unit
Remarks
20
Secondary burner available
0
1
1
0
-
For second burner available
set to ‘1’
21
Standing pilot available
0
1
1
0
-
For DBI application or
Intermittent Pilot operation set
to ‘0
23
Enable secondary burner on
when main burner on
0
1
1
0
-
0 On ignition only main is
switched on
1 On ignition main and
second are switch on in
sequence
2 On ignition main and
second are ignited (even if
second is not switched on)