User's Manual
Security: Upstream AP failed MIC check during BP authentication
Installation and User Guide: Airgo Access Point 305
Security: Upstream AP failed MIC check during BP authentication
Notification that indicates the local BP has determined that the upstream AP has failed a MIC
check on a received frame
S
yntax
"For device-id %s, the upstream AP %s with SSID %s authenticating via local BP
radio %d failed an EAPOL-MIC check with auth-type %d during key exchange %d"
D
escr
i
p
ti
on
This notification is generated when the MIC fails during EAPOL key exchange process via a
BP radio.
U
sage
G
u
id
e
li
nes
This indicates that a frame with a MIC failure has been received during the EAPOL Key
exchange process.
E
xamp
l
es
For device-id AP_00-0A-F5-00-01-89 , the upstream AP 00:0a:f5:00:06:22 with
SSID NewYorkRm authenticating via local BP radio 0 failed an EAPOL-MIC check
with auth-type 4 during key exchange 3
S
ee
Al
so
Alarm Parameters
DeviceId The device ID of the AP
AP The MAC address of the upstream AP
SSID SSID on the AP to which the station has associated
Radio Radio interface on the AP
Authentication Type RSN PSK (3) or RSN EAP (4)
Key Exchange Pairwise key exchange (0) or group key exchange (1)
Alarm Severity
Severity Critical