Operation Manual

WARNING: ALWAYS KEEP THE MUZZLE
POINTED IN A SAFE DIRECTION
Filling/Attaching the Air Tank
Standard Quick Detach Tank System
Air Bleed Screw
Clamp Thumbscrew
Air Tank Seal
Pressure Gauge
Attach to scuba tank K
valve. Clamp thumbscrew
should be nger tight.
Rell Adapter
Rell Adapter Seal
Clamp Bracket
Rell Clamp
If you ll from a scuba tank that has a K-valve, the AirForce rell clamp is the way
to connect your air tank. The square clamp attaches to the K-valve and mates with
the O-ring in the scuba tank valve. Once the rell clamp is attached to the scuba
tank, close the bleed screw and screw the air tank into the adapter.
Filling from a scuba tank
With the rell clamp attached to the scuba tank and the rie’s air tank attached to the
rell clamp, open the scuba tank valve very slowly. Allow at least one minute for
the tank to ll, which you can watch on the gauge. Do not exceed 3,000 pounds per
square inch/206 bar. When the ll is complete, close the scuba tank valve.
To disconnect the air tank from the rell clamp, open the bleed screw. This allows
the high pressure air inside the rell clamp to exhaust, making it possible to unscrew
the air tank.
Leave the rell clamp on the scuba tank or put it in a box. Either way, keep the
clamp assembly as clean as possible.
Attaching the air tank to the rie
To install the tank, push forward on the cocking knob lightly to move the bolt out of
the tank’s way. Screw the air tank into the threaded port at the rear of the rie frame.
The fast-twist threads make tank installation quick and easy, once you have done it a
few times.
WARNING: ALWAYS KEEP THE MUZZLE
POINTED IN A SAFE DIRECTION