Operational Tips
Power adjustments
The rie needs one shot to settle down following a power adjustment. After that, it
should give shots at a consistent velocity.
Removing or disabling the safety mechanism
Disabling or removing any of the safety parts can disable the rie and will void the
warranty and will create a hazardous condition.
Modications to the valve
The valve in the AirForce rie is not a user-maintainable item. Any attempt to
remove or modify the valve in any way will void the warranty and may create a
hazardous condition.
Filling the air tank with a gas other than dry compressed air
or nitrogen
This practice is not recommended and voids the warranty for the rie.
Cleaning the barrel
An airgun barrel seldom needs cleaning. If you do clean the barrel, use a good
quality bore brush of the correct size and use a non-jointed cleaning rod if possible.
Do not use cleaning solvents and agents formulated for rearms because they can
damage the seals and O-rings, rendering the rie inoperative.
Removing jammed pellets from the barrel
Remove the air tank. Remove the end cap (on SS models) to see the actual muzzle
of the barrel. Always attempt to remove jammed pellets from the breech through the
muzzle; only go from the muzzle end if there is no other way. Use a good cleaning
rod of the correct size to push the jam out of the muzzle.