Brochure

Product Summary
• Meets mandatory Building Codes, Energy, Residential, Mechanical, and Green Codes
• Made in The USA
• Superior durable quality with UV/resistance and high impact strength design
• Gasket Compression System Seals Wall Air Leakage and Weather Moisture Wall Damage
• Flexible elastomeric outlet sleeve design offers, anti-wind, anti-rodent features
• Design supports HVAC systems with wall isolation & anti-vibration features
• Flexible Sleeve Reduces Piping Vibration and Noise
Air Leakage Wall Seal, Protect Indoor Air Quality!
The TITAN OUTLET
TM
is the engineered solution for wall sealing HVAC penetra-
tions featuring a wall enclosure system that is weather and air leakage resistant,
controls vibration, is rodent proof, and has become the preferred industry leader.
Seals HVAC Piping Wall Penetrations
TGS Series TSS Series
AIREX TITAN OUTLET
TM
Professionally Engineered and with an Architectural aesthetic finish design, features a Wall Outlet Enclosure
with excellent weather proofing capabilities that fits over and seals around wall surface piping penetrations, utilizing elastomeric gaskets and
seals, as required by building, energy, and mechanical codes. AIREX TITAN OUTLET
TM
prevents wall gaps and exterior surface cracks associat-
ed with the use of rigid wall penetration sleeves or rigid penetration flashing materials. Featuring a combined fastener and gasket/seal applied
compression-force system that accomplishes simultaneous, solid, internal wall structure attachment and all-surface wall gasket mounting for
long-term sustainable and effective air leakage sealing.
An integral over-molded Flexible Elastomeric Sleeve, seals the refrigerant piping and insulation, creating an air leakage seal, that permanently
supports the refrigerant piping at the point of equipment service areas, professionally engineered and with an architectural aesthetic finish
design. The sleeve also features a designated region to accommodate a stainless-steel clamp that mechanically grips both refrigerant piping
and piping insulation, mechanically securing against vibration, rodents, insects, and pipe insulation protection for outdoor usage.
U.S. Patent #9,091,377 B2
#9,523,200 B2
Packaging Packaging
Codes & Standards Compliance
I
n
f
i
l
t
r
a
t
i
o
n
A
i
r
L
e
a
k
a
g
e
B
l
a
z
i
n
g
S
u
n
U
V
R
a
d
i
a
t
i
o
n
S
n
o
w
I
c
e
F
o
r
m
a
t
i
o
n
R
a
i
n
-
W
i
n
d
M
o
i
s
t
u
r
e
M
o
l
d
G
r
o
w
t
h
D
a
m
a
g
e
P
i
p
e
V
i
b
r
a
t
i
o
n
I
n
d
o
o
r
A
i
r
Q
u
a
l
i
t
y
P
r
o
t
e
c
t
i
o
n
R
o
d
e
n
t
s
I
n
s
e
c
t
s
Weather and Physical Damage Protection
Wall Surface Applications
• Brick
• Concrete
• Masonry
• Metal Paneling
• Siding
• Stone
• Stucco
• Drywall
ASTM E283
UL 746C
Air Leakage
Outdoor Suitability - f1 Rating
Outlet Approved Product & Material Testing
ASTM E331
ASTM E2178
Water Penetration
Air Permeability
ASTM D1525C-09 - Temperature Deformation
ASTM D648-07 - Temperature Load Deformation
UL 94 HB - Flammability
ASTM D573-04 - Deterioration
ASTM D746-07 - Brittleness Temperature
Other Pertinent Material Tests
Air Leakage (Mandatory) Section R402.4.1, R402.4.1.1, R402.4.1.2
(2012, 2015); R402.4, R402.4.1.1, R402.4.1.2 (2018)
Building Thermal Envelope - Penetrations
• 2012, 2015, 2018 International Residential Code (IRC)
Chapter 11 Part IV Energy Efficiency
• 2012, 2015, 2018 International Energy Conservation Code
(IECC)
• 2012, 2015, 2018 International Mechanical Code
(IMC) Chapter 3
• 2012, 2015, 2018 International Building Code (IBC)
Appendix F
Rodent Proofing F101.3
• 2016, 2019 California Building Energy Efficiency
Standards (TITLE 24 ENERGY CODE)
Commercial, Residential Sections
• 2016, 2018 Uniform Mechanical Code (UMC)
Chapter 11 Refrigeration
Air Barrier Penetration (2018) - C402.5.1.1
Penetrations of the air barrier shall be caulked, gasketed or otherwise
sealed... Sealing shall allow for expansion and contraction of
materials and mechanical vibration.
Air Leakage (Mandatory) - C402.4 & C402.4.2 (2012);
C402.5 & C402.5.1.1(3) (2015, 2018)
Scope 1101.0; General 1106.0; Support 1106.2; Piping Vibration
& Strain 1111.1; Support 1111.2...piping and tubing shall be
securely fastened to a permanent support within six (6) feet from…
the compressor; Visual Inspection 1111.4
General 301.1; Energy Utilization 301.2; Listing, Labeling 301.7;
301.11; Vibration Isolation 301.13; Rodent Proofing 301.17; Wind
Resistance 301.15; Piping Support 305, 305.1, 305.2, 305.4;
Refrigeration Piping 1107 ASME B31.5
Air Leakage (Mandatory) - Section 110.7 All joints, penetrations and
other openings in the building envelope that are potential sources of
air leakage shall be caulked, gasketed, weather stripped, or otherwise
sealed to limit infiltration and exfiltration.
General N1101; Scope N1101.1; Air Leakage N1102.4;
Building Thermal Envelope N1102.4.1 -
(1. All joints, seams, penetrations)
Residential
Commercial
6