User manual
U-See User Manual - Settings Menu
2.12.10
2.12.10
U-See settings
U-See settings
Under this menu entry are grouped all the options that affect the behaviour of the U-See
program and are not strictly associated with an UAV.
Available settings are grouped in four main categories. One by one description will be
given hereafter
2.12.10.1 Alarms & Warnings
Alarms & Warning section allow to change and fine-tune the behavior of the U-See Alarm
system.
This section is divided in three main sections:
• Battery related on-ground alarms: It is possible to define values at which U-See will
launch an alarm, independently of autopilot on-board own alarms limits. This
section allows to define a battery voltage alarm per every available channel. If at
any point the voltage of the channel drops below the configured voltage, the
corresponding ADC channel alarm will trigger. It is possible to define also a
threshold percentage of battery below which ENG alarm will be triggered. For this
alarm to work as designed, it is important to input the correct battery available
capacity in Engine Data (See 2.8.7.1 Electric engine Data)
• General Alarm configuration: Through this section alarms can be configured to emit
a sound whenever its status changes to an abnormal condition, and also, it is
possible to make the triggered alarm blink until the user acknowledges the alarm by
clicking on it. This prevents intermittent problems go unadvertised and we strongly
recommend to activate both features. When configured to blink, alarms will
continue to blink even if they return to nominal status.
• GPWS warning levels: The last section of the window allows configuration of the
GPWS warning system levels. Rotary and fixed wing may have different warning
levels. Altitudes introduced in this section are AGL (Above Ground Level) indications
and the dialog will force the critical value to be lower than the warning level and
those two lower than the low altitude level. For more information, see 2.5.3 GPWS
Information display
Document Version 1.25 69
Figure 61: Alarms & Warnings