User manual
U-See User Manual - Settings Menu
Also adjustable, the sensitivity of the normal, fast and slow movement.
Test should be made while on ground to assure this settings suite your application or
preferences regarding camera movement.
2.12.5
2.12.5
Payload setting window
Payload setting window
Camera installation type can be adjusted with this dialog. Available options are:
• Pan-Tilt Servos: Two axis pan-tilt servo operated camera
• Roll-Tilt Servos: Two axis roll-tilt servo operated camera
• Open Loop Servos: No feedback modified servos.
Serial driver section allows to select what kind of RS-232 commands will be output through
the payload serial port. Current supported protocols are Sony VISCA protocol and Controp
protocol. Other camera interface options can be added on request.
Pan-Tilt and Roll-Tilt servo option needs extra information: Angles obtained by servo
deflection has to be input for the system to know how much PWM variation needs to
command for camera control. Full deflection and neutral deflection has to be given for
proper operation of the camera.
Declared minimum, neutral and maximum angles for pan and tilt do affect VISCA and
CONTROP protocol controlled cameras, as the autopilot will never exceed these declared
limits.
2.12.6
2.12.6
Air Data System Settings
Air Data System Settings
Adjustment to the Air Data Acquisition is made trough this window.
Document Version 1.25 63
Figure 55: Payload configuration