User manual
U-See User Manual - File Menu
2.6.1.2.1 Serial port for export
Telemetry data is re-exported using a serial-port. Port Speed, data width, stop bit number
and parity are configurable.
Said data exported is formatted according to the selected data protocol.
Current standard protocols for serial export are:
• NMEA 0183: Due to limitations in the NMEA protocol, only the current position and
altitude is exported with NMEA protocol.
2.6.1.2.2 Networks → server of data.
No matter what is the actual source of the data, U-See can retransmit said data to other
computers using a TCP/IP connection.
To enable this behavior, select the desired port to listen on
9
and check the Act as a server
of data checkbox. To disable, un-check the option.
Up to 8 clients may connect to a data server, although this number can be increased by
using daisy chaining.
Protocol of the exported data can be selected through the available menu. Current
protocols available through network are:
• Airelectronics' telemetry data: To expose the data to another U-See instance
• NMEA 0183 position data: Due to limitations in the NMEA protocol, only the current
position and altitude is exported with NMEA protocol.
2.6.1.2.3 Extra export protocols
Your U-See version may have extra available export protocols. Please check specific
documentation for those options.
Extra protocols can be developed upon request. Please, contact Airelectronics for details.
9 Elevated privileges may be necessary for ports under 1024
Document Version 1.25 18