Technical data
-
V
Precision Air Conditioning
Precision Air Conditioning
72
Technical Manual : 6258867 F 07/2012
General Specification - Condensing Units CUS 3 - 30D
MECHANICAL DATA
CUS3
CUS4
CUS5
CUS5.5
CUS6
CUS6.5
Capacity
Nom Cooling Capacity (1) kW 8.7
13.1
13.7
15.2
17.9
19.3
Nom Input (1) kW 3.0
3.8
5.1
5.2
6.4
6.6
Capacity Steps
% 0-100
0-100
0-100
0-100
0-100
0-100
Dimensions
Height mm 1130
1130
699
699
699
699
Width mm 937
937
1213
1213
1213
1441
Depth mm 395
395
865
865
865
996
Weights
Machine kg 85.0
101.0
138.0
140.0
141.0
236.5
Operating kg 88.1
104.1
141.0
143.0
144.0
241.5
Construction
Material/Colour Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey (RAL 7035)
Condenser
Air Cooled - Copper Tube/Aluminium Fins
Quantity 1
1
2
2
2
3
Total Face Area m² 0.89
0.89
0.69
0.69
0.69
1.03
Nominal Airflow m³/s 0.80
1.80
2.00
2.00
2.00
2.25
Discharge Horizontal
Horizontal
Vertical
Vertical
Vertical
Vertical
Fan & Motor
Axial
Quantity 1
2
1
1
1
1
Diameter mm 450
450
630
630
630
630
Maximum Speed rpm 840
840
930
930
930
930
Compressor
Single - Scroll
Quantity 1
1
1
1
1
1
Oil Charge Volume (Total) l 1.10
1.60
1.55
1.65
1.65
4.10
Refrigeration
Single Circuit
Refrigerant Type R407C (Optional R22)
Refrigerant Charge (2) kg 1.50
1.50
2.40
2.40
2.40
3.63
Coil Volume (3) l 5.12
5.12
8.00
8.00
8.00
12.00
Connections
Liquid Line in Flare 3/8
Flare 1/2
Flare 1/2
Flare 5/8
Flare 5/8
Flare 5/8
Suction Line in Flare 3/4
Flare 3/4
Sweat 7/8
Sweat 7/8
Sweat 7/8
Sweat 1 1/8
Hot Gas Stub in 1/2
1/2
5/8
5/8
5/8
5/8
CUS7.5
CUS8.5
CUS10
CUS12
CUS30D
Capacity
Nom Cooling Capacity (1) kW 21.0
23.6
27.4
35.7
80.7
Nom Input (1) kW 6.6
8.0
10.0
11.5
28.8
Capacity Steps - Per Circuit
% 0-100
0-100
0-100
0-100
0-100
Dimensions
Height mm 699
953
953
953
1438
Width mm 1441
1770
1770
1770
3000
Depth mm 996
865
865
865
1100
Weights
Machine kg 203.5
242.0
242.0
247.0
695
Operating kg 208.5
261.0
261.0
266.0
705
Construction
Material/Colour Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey (RAL 7035)
Condenser
Air Cooled - Copper Tube/Aluminium Fins
Quantity 3
2
2
2
2
Total Face Area m² 1.03
1.37
1.37
1.37
3.46
Nominal Airflow m³/s 2.25
4.45
4.45
4.45
6.80
Discharge Vertical
Vertical
Vertical
Vertical
Vertical
Fan & Motor
Axial
Quantity 1
2
2
2
3
Diameter mm 610
610
610
610
610
Maximum Speed rpm 930
930
930
930
930
Compressor
Single - Scroll
Quantity 1
1
1
1
2
Oil Charge Volume (Total) l 3.25
3.80
3.80
4.00
6.60
Refrigeration
Single Circuit Dual Circuit
Refrigerant Type R407C (Optional R22)
Refrigerant Charge (2) kg 3.63
4.76
4.76
4.76
9.00
Coil Volume - per circuit (3) l 12.00
15.70
15.70
15.70
21.0
Connections
Liquid Line in Flare 5/8
Sweat 7/8
Sweat 7/8
Sweat 7/8
Sweat 5/8
Suction Line in Sweat 1 1/8
Sweat 1 1/8
Sweat 1 1/8
Sweat 1 3/8
Sweat 1 3/8
Hot Gas Stub in 5/8
7/8
7/8
7/8
N/A
(1) Nominal Capacity based on 5°C evaporating temperature and a 35°C ambient.
(2) CUS 3 - 4 are precharged with refrigerant. CUS 5 - 30D are supplied with holding charge of inert gas.
(3) Figures for guidance.
OUTDOOR UNIT