Operating instructions

6
Measure the distance from the fan discharge tube, after the unit is clamped down to
the ceiling. This is dimension ā€œAā€
Add 15mm which is the overlap distance of the extension duct over the
fan tube.
Extension duct length is therefore A + 15 mm = ā€œDā€
Cut the extension duct to this length. See Fig 9
Fig 9
Fit the circular duct to the fan discharge tube engaging the notch over the fan cable.
See Fig 10