Specifications

HighInletTemperatureRefrigeratedAirDryer
15
WARNING!
• Toavoidpossiblehazardorinjury,
the operator should be fully familiar
with the high inlet temperature
series refrigerated air dryer system
and its operation.
• Whenthesystemisshutdownand
power removed, lock out power
supply and depressurize system
before performing maintenance
or service work to avoid injury to
personnel or property damage.
Shut-Down Procedures
Shut-Down Emergency
The high inlet temperature series refrigerated
air dryer system can be shut down under any
conditions and at any time by turning the unit off
at the dryer or at the main disconnect switch. Once
power is removed from the dryer system, the dryer
must be isolated from the compressed air stream to
avoid a refrigeration circuit over pressure situation.
Short-Term Shut-Down (over night or weekends)
The high inlet temperature series refrigerated air
dryer system can be shut down at any time by
turning the unit off at the dryer by using the on/off
switch or at the main disconnect switch.