Specifications
23
Non-CyclingRefrigeratedAirDryer
Problem Probable Cause Remedy
Low air pressure
downstream due to
continuous air flow
through the moisture
drain line.
Failedorshortcircuited
timer on drain.
Replacetimerdrain.
Faileddrainsolenoid. Replacetimerdrain.
Solenoidvalvestuckopen. Ifpowerisoffandtheairstopsleaking,replace
thetimerdrain.Ifpowerisoffandaircontinues
leaking,cleanthetimerdrain.
Noiseorvibration
coming from refrigerated
air dryer system.
Shippingdamagehascaused
compressor mounting to
loosen.
Checkallmountingboltsoncompressorand
tighten.
Cabinet panels or support
beams loosened during
shipping.
Checkallscrewsandboltsondryersystemand
tighten.
Loose mounting bolts,
bent fan blade or worn
bearings on condenser fan
motor.
Tighten bolts, straighten or replace fan blade or
replace motor.
Noisecomingfrom
refrigeration compressor
due to liquid refrigerant
in compressor - caused
by shipping or moving
of dryer.
Letdryersystemsitforsixhourstoallow
refrigerant to settle out of compressor and to
allowcrankcaseheatertowarmcompressor.
Timerdrainstuckopen. Failedordirtytimerdrain. Ifpowerisoffandtheairstopsleaking,replace
thetimerdrain.Ifpowerisoffandaircontinues
leaking,cleanthetimerdrain.