Troubleshooting (cont’d)
Problem Probable Cause Remedy
Dryer Fails to
Shift Towers
Exhaustvalves(s)not
functioning
Checkpilotvalveandpilotairsupply,dismantle
andcleanexhaustvalvecheckflowcontrolvalve
attachedtopurgeexhaustvalveactuatormay
notbeadjustedproperly(shouldbeadjustedso
exhaustvalveopenswithina8-12secondtime
period)
Noinputpower Checkthatdryerisonwithcorrectvoltage.
Controller failure Check,replaceifneeded
Pilotairsupplyrestricted Checkpilotfilter,andpilottubingrestriction.
OutletPurgefloworifice
may be clogged
Dismantleoutletpurgefloworificeandclean
out orifice
Inletvalvemalfunction
Dismantle,clean,andreinstallreplacesealsif
needed
Outlet valve malfunction
Dismantle,clean,andreinstallreplacevalveif
needed
Purge Failure Purgemufflerclogged Remove and clean, replace if needed
OutletPurgefloworifice
may be clogged
Dismantleoutletpurgefloworificeandclean
out orifice
Controller failure Check,replaceifneeded
Exhaustvalves(s)not
functioning
Checkpilotvalveandpilotairsupply,dismantle
andcleanexhaustvalvepurgeexhaustvalve
actuatormaynotbeadjustedproperly(should
beadjustedsoexhaustvalveopenswithina8-12
secondtimeperiod)checkcontrolsystem
Pressurization
Failure
OutletPurgefloworifice
may be clogged
Dismantleoutletpurgefloworificeandclean
out orifice
Exhaustvalves(s)not
functioning
Checkpilotvalveandpilotairsupply,dismantle
andcleanexhaustvalvepurgeexhaustvalve
actuatormaynotbeadjustedproperly(should
beadjustedsoexhaustvalveopenswithina8-12
secondtimeperiod)checkcontrolsystem