Specifications
20
Troubleshooting (cont’d)
Problem Probable Cause Remedy
High Dewpoint High inlet air flow Reduce inlet air flow
Inletairtemperatureabove
design spec
Reduce inlet air temperature to design spec
Poorpre-filtration Checkpre-filterelement,replaceifneeded
Inletairpressurebelow
design spec
Increasepressuretothedryer
Desiccantcontaminated Replace desiccant
OutletPurgefloworifice
may be clogged
Dismantleoutletorificeandcleanoutthe
orifice
Backpressurein
regenerating chambers
Mufflersareclogged,installnewmufflers
Exhaustvalve(s)notfully
opening or closing
Checkpilotvalveandpilotairsupply,
dismantleandcleanexhaustvalve,checkflow
controlvalveattachedtopurgeexhaustvalve
actuatormaynotbeadjustedproperly(should
beadjustedsoexhaustvalveopenswithina
8-12secondtimeperiod)
Inletvalveleaking Dismantleandclean,replacesealsifneeded
Noinputpower Checkthatdryerisonwithcorrectvoltage
Noinputpower Checkthatdryerisonwithcorrectvoltage
Controller failure Check,replaceifneeded
High-Pressure Drop Low inlet pressure Increaseinletpressuretodesignpressure
Desiccantdusting High inlet flow velocities due to high flow
Inletprefilterdirty Inspectandreplaceasneeded
High inlet flow rate Reduce inlet flow rate to meet dryer spec
Outlet filter dirty Inspectandreplaceasneeded
Desiccantdiffuserscreens
clogged
Inspectedandcleanifneeded
High Back Pressure in
Regenerating Tower
Purgemufflerclogged Clean and replace if needed
Desiccantdiffuserscreens
clogged
Inspectedandcleanifneeded
Restrictivepurgeexhaust
piping
Clean and replace with larger pipe if required
AircelAHLDE-Series-Models1000-5000