HeatlessRegenerativeDesiccantAirDryer
Maintenance
Priortoperforminganymaintenanceonthedryer,allpersonnelarestronglyadvisedtofamiliarize
themselves with the equipment by reading the entire contents of this operation manual. Aircel strongly
recommends the strict adherence of all the safety procedures prior to any performing any maintenance
activity on the dryer.
A. Thepressuredifferentialindicatorreferredtoasthe“Delta-P”isaverygoodindicatorofthestate
ofthefilterelements.Maintenancepersonnelmustpayattentiontothesetokeepthedryerrunning
withfullefficiencyChangefilterelementsonaregularbasis,onceayearmaximumfora1-shift
operation. Change more frequently if operating 2 or 3 shifts such as every 6 months.
B. Theusefullifeofafilterelementdependsonthequalityofair.Freeopenareasforinputand
exhaustwillensurelesserintakeofdirtandparticles.
C. Powdereddesiccantcanaccumulateinthemufflerandincreasethebackpressureintheregenerating
tower change mufflers on a regular basis typically every 2-3 months for optimum performance.
D. Oilandoilvaporcandrasticallyreducethelifeofthedesiccant.Takeprecautionstoeliminateall
traces of oil from the airflow
E. Fluctuatingdewpointindicatesunevendryingandregenerationbetweenthetowers,anexhaust
valvemaynotbeworkingproperlyormufflermaybecloggedordirty,alsovesseldiffuserscreen
may be clogged.
Weekly Checklist
1. Checkalldrainvalves,prefilter,afterfilterandseparators
2. Checkanypressuredifferentialindicators(Delta-P)onthepre-filterandafterfilter(filterelements
shouldstillbechangedonregularbasisonceayearmaximumfora1shiftoperation.Changemore
frequentlyifoperating2or3shiftssuchasevery6months.).
3. Checkdryerforcorrectoperation.
4. Verifydryerispurgingatthepurgeexhaust,afterdryerdepressurizes.
5. Checkthedewpoint(ifavailable)toensurethedewpointisbeingachieved.
6. Checkbackpressureinregeneratingtower,ifmorethanafewpsigonthepressuregauge,clean
orreplaceexhaustmufflers(Changemufflersonaregularbasistypicallyevery2-3monthsfor
optimumperformance).