Instruction manual

7. Maintenance
ALWAYS ENSURE THAT THE MAIN
EXTERNAL ELECTRICITY SUPPLY IS
SWITCHED OFF BEFORE COMENCING ANY
MAINTENANCE ON THIS HEATER.
To obtain the best results from the heater, it is
essential to avoid the accumulation of dust and
dirt within the unit on the air inlet and discharge
grilles.
For this reason regular cleaning is necessary,
paying particular attention to the removal of dirt
build up on the rotor blades.
Cleaning of the fan is best carried out with a soft
brush.
A single drop of light oil should be applied to the
motor bearing from time to time.
All heaters are fitted with motor thermal protection.
Other faults in relation to the element, motor and
wiring should be identified using conventional fault
finding techniques.
In the event that electrical components are
replaced, please ensure that electrical safety
checks in accordance with the regulations in force
in the country of use are undertaken.
8. Spares & Servicing
It is essential when ordering spares or
replacement parts to state the model number and
the serial number on the rating label adhered to
the rear of the unit.
The heater should be serviced annually. Airbloc
offer a service facility, call 01384 489700.
Servicing shall be undertaken by a competent
person.
Any repair or alteration carried out to this product
without the prior authority from AmbiRad will
invalidate warranty.
Refer to Air Curtain Installation and Operating
Instruction manual for details.
Ensure electrical power is isolated from the
product.
9. Replacement Parts
ALWAYS ENSURE THAT THE MAIN
EXTERNAL ELECTRICITY SUPPLY IS
SWITCHED OFF BEFORE COMMENCING ANY
WORK ON THIS HEATER.
9.1 TO REPLACE A FAN/HEATER ASSEMBLY
Switch off the mains supply.
Split and remove shroud (Surface Mount
only)
Remove the grille.
Disconnect the internal wiring from the
blower
Remove the four screws fixing the fan
heater assembly to the back case
The fan heater assembly can now be eased
forward and removed from the heater case
Fit replacement unit and re-assemble in the
reverse order.
9.2 TO REPLACE A SWITCH IN THE CONTROL
BOX
Switch off the mains supply.
Remove the switch box cover.
Disconnect the wiring to the switch.
Remove the appropriate fixing screw(s) and
push out the switch.
Fit the replacement switch, reconnect the
wiring and replace the cover.
WARNING:
THIS HEATER SHOULD NOT BE
INSTALLED WHERE THERE IS A
CORROSIVE ATMOSPHERE.