Instruction manual
Figure 16. Mounting and installation views Surface Mount 
6.1 Control 
The  remote  control  box  houses  2  switches,  a 
double  pole  and  a  single  pole,  and  gives  the 
following functions: 
  Switch ’FAN’ on = Off/Fan Only 
  Switch ’I’ on = ⅓ Heat 
  Switch ’II’ on = ⅔ Heat 
To switch on the appliance and operate the blower 
in  Ambient  mode,  depress  the left-hand  switch 
(marked “FAN”). 
When  the  centre  switch  only  (marked  ‘I’)  is 
depressed  the  heat  output  is  ⅓  of  full  heat. 
ACT03-1 = 1.0kW, ACT04-1 = 1.5kW, ACT06-1 = 
2.0kW.  
When  the  right  hand  switch  only  (marked  ‘II’)  is 
depressed  the  heat  output  is  ⅔  of  full  heat. 
ACT03-1 = 2.0kW, ACT04-1 = 3.0kW, ACT06-1 = 
4.0kW.  
When  both  the  centre  switch  and  the  right-hand 
switch  are  depressed  the  full  heat  output  is 
available.  ACT03-1  =  3.0kW,  ACT04-1  =  4.5kW, 
ACT06-1 = 6.0kW 
6.2 Protection 
The unit is protected in the event of fan failure, or 
an  obstruction  of  the  free  air  flow,  by  a  thermal 
PTC Self Hold Cut Out. 
Having  tripped the  PTC  Cut  Out remains  open, 
effectively  switching  off  the  heating  elements,  as 
long  as  mains  power  is  available  inside  the 
appliance. 
The  PTC  Cut  Out  will  only  reset  when  the  
appliance is switched OFF and allowed to cool for 
at least 20 minutes. 
6.3 To reset the PTC Self Hold Cut Out 
a)  The cut-out is reset by switching OFF mains 
power to the appliance. 
b)  Allow the appliance to cool for 20 minutes. 
Re-start,  switch  ON  the  appliance.  If  the  Cut-out 
trips  again,  a  qualified  electrician  should  be 
consulted. 
Figure 17. Remote Control Box 
6. User Instructions. 