SDS
D8284821 v2.0
Conforms to USDOL OSHA 29CFR 1910.1200 HAZCOM
6. Accidental release measures
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Approach release from upwind. Prevent entry into sewers,
water courses, basements or confined areas. Wash spillages into an effluent treatment
plant or proceed as follows. Contain and collect spillage with non-combustible,
absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in
container for disposal according to local regulations (see Section 13). Dispose of via a
licensed waste disposal contractor. Contaminated absorbent material may pose the
same hazard as the spilled product. Note: see Section 1 for emergency contact
information and Section 13 for waste disposal.
Large spill
:
7. Handling and storage
Conditions for safe storage,
including any
incompatibilities
Store between the following temperatures: 5 to 30°C (41 to 86°F). Store in accordance
with local regulations. Store in a segregated and approved area. Store in original
container protected from direct sunlight in a dry, cool and well-ventilated area, away
from incompatible materials (see Section 10) and food and drink. Eliminate all ignition
sources. Separate from oxidizing materials. Keep container tightly closed and sealed
until ready for use. Containers that have been opened must be carefully resealed and
kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate
containment to avoid environmental contamination.
:
Protective measures
Put on appropriate personal protective equipment (see Section 8). Persons with a
history of skin sensitization problems should not be employed in any process in which
this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid
breathing vapor or mist. Use only with adequate ventilation. Wear appropriate
respirator when ventilation is inadequate. Do not enter storage areas and confined
spaces unless adequately ventilated. Keep in the original container or an approved
alternative made from a compatible material, kept tightly closed when not in use. Store
and use away from heat, sparks, open flame or any other ignition source. Use
explosion-proof electrical (ventilating, lighting and material handling) equipment. Use
only non-sparking tools. Empty containers retain product residue and can be hazardous.
Do not reuse container.
:
Precautions for safe handling
Benzyl alcohol
AIHA WEEL (United States, 10/2011).
TWA: 10 ppm 8 hours.
Benzyl acetate
ACGIH TLV (United States, 4/2014).
TWA: 10 ppm 8 hours.
TWA: 61 mg/m³ 8 hours.
8. Exposure controls/personal protection
Ingredient name
Exposure limits
Environmental exposure
controls
:
Emissions from ventilation or work process equipment should be checked to ensure
they comply with the requirements of environmental protection legislation. In some
cases, fume scrubbers, filters or engineering modifications to the process equipment
will be necessary to reduce emissions to acceptable levels.
Appropriate engineering
controls
:
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or
other engineering controls to keep worker exposure to airborne contaminants below any
recommended or statutory limits. The engineering controls also need to keep gas,
vapor or dust concentrations below any lower explosive limits. Use explosion-proof
ventilation equipment.
Control
Occupational exposure limits
5/15
05/10/2017
Date of issue
:
SDS #
8278319_D8284821
(NA)
:
Code #
D8284821 v2.0
: