Instruction Manual

6
Operation Instruction: 110V or 220V outlet
© Air Venturi
®
2018 / www.airventuri.com / 216-292-2570
9
10
11
12
13b
CAUTION:
Air and/or liquid may be released at
high velocity from the bottom of the unit. Keep ngers/
hands/eyes clear from the bottom of the unit when
opening the pressure release/bleed screw.
9) Once the fans are running, depress the ON/OFF
button to begin lling (g. 9).
Note: You can stop the ll process at any time by depressing the
ON/OFF button. If you do stop the ll for any reason, you MUST
bleed the pressure in the line before resuming lling. If you DO
NOT bleed the pressure in the line and just depress the ON/OFF
button to resume lling, the Nomad II will automatically stop after a
few seconds of running.
10) Once the pre-set ll pressure is reached, the
compressor will stop (g. 10).
NOTE: The cooling fans will continue to run.
11) Release/Bleed the pressure in the system by
turning the pressure release/bleed screw counter-
clockwise (g. 11).
12) Once the pressure is released and the pressure
gauge on the compressor reads 0 PSI/BAR,
disconnect the hose from the lled device by pulling
back the collar on the female quick disconnect tting
and at the same time, pulling it off of the male tting
it was connected to (g. 12).
13) To power down your Nomad II, depress the
POWER/RESET button (g. 13a) and the LOAD
gauge and compressor fans will turn off. Unplugging
the three prong connecter (g. 13b)from your 110V
outlet will turn off the power converter fan.
!
13a