Instruction Manual
6
Operation Instruction: 110V or 220V outlet
© Air Venturi
®
2018 / www.airventuri.com / 216-292-2570
9
10
11
12
13b
CAUTION:
Air and/or liquid may be released at
high velocity from the bottom of the unit. Keep ngers/
hands/eyes clear from the bottom of the unit when
opening the pressure release/bleed screw.
9) Once the fans are running, depress the ON/OFF
button to begin lling (g. 9).
Note: You can stop the ll process at any time by depressing the
ON/OFF button. If you do stop the ll for any reason, you MUST
bleed the pressure in the line before resuming lling. If you DO
NOT bleed the pressure in the line and just depress the ON/OFF
button to resume lling, the Nomad II will automatically stop after a
few seconds of running.
10) Once the pre-set ll pressure is reached, the
compressor will stop (g. 10).
NOTE: The cooling fans will continue to run.
11) Release/Bleed the pressure in the system by
turning the pressure release/bleed screw counter-
clockwise (g. 11).
12) Once the pressure is released and the pressure
gauge on the compressor reads 0 PSI/BAR,
disconnect the hose from the lled device by pulling
back the collar on the female quick disconnect tting
and at the same time, pulling it off of the male tting
it was connected to (g. 12).
13) To power down your Nomad II, depress the
POWER/RESET button (g. 13a) and the LOAD
gauge and compressor fans will turn off. Unplugging
the three prong connecter (g. 13b)from your 110V
outlet will turn off the power converter fan.
!
13a