1) Plug the power cord into the Nomad II (g. 1). DO NOT
plug the three prong connector into an active wall outlet yet.
2) Plug the 110V three prong connector into your wall outlet
(g. 2). Once plugged in, the fan on the power converter
will turn on. The compressor fans and LOAD gauge will not
come on yet.
NOTE: If connecting to a 220V outlet, an outlet adapter will be necessary to
use the included power cord.
3) Set the desired ll pressure via the dial on the top of the
pressure gauge (g. 3).
4) Make sure the connection between the female quick
disconnect on the hose and the male connection on the
compressor are tight (g. 4).
5) Close the bleed/pressure release valve by turning it
clockwise until it is tight (g. 5).
6) On the underside of the unit, locate the “Moisture Release
Valve” and turn clockwise (g. 6) until tight to close it.
7) Connect the output hose to the device you wish to ll via
the female quick disconnect tting (g. 7).
PLEASE NOTE: If you are lling a PCP airgun from empty, you may need to
cock the gun before starting the ll process. Consult the owner's manual of
your airgun for further instructions.
8) Once these steps are complete, depress the POWER/
RESET button. The LOAD gauge will illuminate and the
compressor fans will begin to run (g. 8).
5
Operation Instruction: 110V or 220V outlet
1
2
4
5
© Air Venturi
®
2018 / www.airventuri.com / 216-292-2570
CAUTION:
Always check and make sure the collar
on the female quick disconnect is in the forward position
and secure on the male tting you are connecting it to.
It is recommended that you check the connection by
attempting to pull the female and male ends apart while
the collar on the female tting is in the forward position.
3
6
7
8
DO NOT OVERFILL AIR
CYLINDERS OR AIR GUN
TANKS, AS THIS CAN CAUSE SERIOUS INJURY OR
DEATH. NEVER SET THE OUTPUT PRESSURE/AUTO
SHUT OFF ABOVE 4500 PSI (310 BAR).
WARNING
!
!
CAUTION:
Always check and make sure the collar
on the female quick disconnect is in the forward position
and secure on the male tting you are connecting it to. It is
recommended that you check the connection by attempting
to pull the female and male ends apart while the collar on