Instruction Manual
12
Troubleshooting
Issue - Burst disc failure
- Resolution - Should the burst disc fail
during use of the compressor, depress
the ON/OFF button and make sure the
compressor has stopped. Open the
Pressure Release Valve to let the
remaining air vent from the compressor.
Once you have veried the burst disc
has failed (there will be a hole in it) by
removing the burst disc retention screw
(pictured right), remove the broken burst
disc from the unit. You will nd
additional burst discs in the bag of spare
parts that comes with the compressor.
Install a new burst disc, and re-insert
the burst disc retention screw by turning
clockwise. If you do not have additional
burst discs, contact Air Venturi for
replacement at: 216-220-1180.
© Air Venturi
®
2018 / www.airventuri.com / 216-292-2570
In the unlikely event that your compressor malfunctions, DO NOT ATTEMPT
TO FIX THE PROBLEM YOURSELF. Please call Air Venturi’s service line so we
can address any issues or have you return the compressor for repair. Air
Venturi Service Line: 216-220-1180
Issue - Compressor will not start
- Resolution - Make sure power converter is plugged into a functional electrical
outlet and make sure power converter is properly plugged into the compressor.
If using a 12V battery, make sure the jumper cables are properly connected as
detailed in the instructions.
Issue - Compressor is not building pressure
- Resolution - Make sure the moisture release valve and the pressure release valve
are closed. They should be hand tightened. If release valves are closed and the
compressor is still not building pressure, contact Air Venturi by calling:
216-220-1180.
Issue - Compressor shuts off before reaching desired pressure.
- Resolution - Make sure the Output Pressure Dial (Auto Shut Off) is set properly.