Purging the Lubrication System
Every 20 lls it is important to purge the Nomad II
of excess silicone oil and moisture. Once you have
completed the 20th ll with your Nomad II, before
opening the Pressure Release Valve, locate the
Moisture Release Valve on the underside of the unit.
Turn the Moisture Release Valve counter-clockwise
to purge the system. (g. 1)
AIR AND / OR LIQUID MAY BE RELEASED AT HIGH
VELOCITY.
IMPORTANT
!
1
Basic Maintenance
Maintenance should be performed at the following times:
1) If oil has been added recently and the LOAD gauge still reads 28 or higher.
2) If ll times increase without any signs of leaking.
3) Once every 20-30 lls.
Turn on the Nomad II compressor and open the Moisture Release Valve on the
underside of the unit by turning the knurled screw counter-clockwise. Add 2-3 drops of
silicone oil into the lubrication hole repeatedly in 30 second intervals, six times. (That’s
a total of 12-18 drops over 2:30 - 3 minutes). Once complete, allow the compressor
to run for another 3 - 5 minutes with the Moisture Release Valve open to allow the
lubricant to circulate in the system. When nished, turn the compressor off and close
the Moisture Release Valve by turning the knurled screw clockwise until tight.
IMPORTANT
FAILURE TO PERFORM BASIC MAINTENANCE AS
DETAILED ABOVE WILL VOID YOUR WARRANTY.