Instruction Manual
10
Output Air Filter Replacement
NOTE: It is recommended that you replace the Air
Filter every 2-3 hours of use. Should you require extra
Air Filters, they can be purchased through Air Venturi.
(216-220-1180).
1) Remove the lter and hose assembly from the
compressor unit by pulling back the collar on the female
quick disconnect tting and pulling the lter away from
the compressor (g. 1).
2) Find the seam in the lter housing (g. 2.1), twist the
large half counter-clockwise, unscrewing it until the unit
separates (g. 2.2).
3) Locate the cartridge lter inside of the large half of
the lter housing (g 3.1). Remove it with tweezers or by
puncturing it with an allen key and pulling it out of the
housing (g. 3.2).
4) Once the used lter is removed, replace it with a new
cartridge lter by pressing the new lter into the large
half of the housing (g. 4).
5) Reassemble the lter housing by screwing the small
and large halves together, turning the large half
clockwise until it is hand tight (g. 5).
6) Re-attach the female quick disconnect to the
compressor by pulling back on the collar on the female
while pressing it onto the male tting. Make sure the
collar is in the forward/locked position before attempting
to run the compressor.
1
2.2
3.1
3.2
4
2.1
5
© Air Venturi
®
2018 / www.airventuri.com / 216-292-2570
Lubricating your Nomad II Compressor
Locate the lubrication hole on the left hand side of the unit. Using the included oil
applicator bottle, apply 2-3 drops of silicone oil every
5 lls or 1.5 hours of use (whichever comes rst).
The “LOAD” gauge on the top of the Nomad II can also be
used to determine oil application intervals. If the LOAD
gauge reaches 28 during operation, it is necessary to
apply silicone oil. The Nomad II will automatically shut off if the LOAD gauge exceeds 29.
IMPORTANT: Use only silicone oil to lubricate the compressor. The use of any other oil/lubricant is not
recommended and may void your warranty.