User Instruction Manual Nomad II 4500 PSI Portable Air Compressor AV-MCOMP4500-2 Ver.
Contents Parts Included.............................................................3 Setting up your Nomad II Compressor........................ 4 Operation Instructions: 110V or 220V outlet.............5-6 Operation Instruction: 12V Battery...........................7-8 Operation the Lights....................................................9 Installing the Foot Extensions.....................................9 Lubricating your Nomad II Compressor..................... 10 Output Air Filter Replacement......
Parts Included 1. Replacement fuse 2. Male QD fitting & test plug 3. Replacement burst disks 4. Spare O-rings 5. Replacement valve springs 6. Replacement seals 7. Oil applicator bottle 8. Jumper Cables 9. Replacement filters 10. Foot extensions 11.
Setting up your Nomad II Compressor Your Nomad II comes pre-set to operate from an 110V outlet. Should you choose to use the unit with a 220V outlet, complete the following steps. 1) The cover must be removed. Before removing, make sure the compressor is not connected to an active electrical outlet. Start by removing each of the 12 phillips head screws, with a phillips head screwdriver turning them counter-clockwise (fig. 1).
Operation Instruction: 110V or 220V outlet 1) Plug the power cord into the Nomad II (fig. 1). DO NOT plug the three prong connector into an active wall outlet yet. 2) Plug the 110V three prong connector into your wall outlet (fig. 2). Once plugged in, the fan on the power converter will turn on. The compressor fans and LOAD gauge will not come on yet. NOTE: If connecting to a 220V outlet, an outlet adapter will be necessary to use the included power cord.
Operation Instruction: 110V or 220V outlet 9) Once the fans are running, depress the ON/OFF button to begin filling (fig. 9). Note: You can stop the fill process at any time by depressing the ON/OFF button. If you do stop the fill for any reason, you MUST bleed the pressure in the line before resuming filling. If you DO NOT bleed the pressure in the line and just depress the ON/OFF button to resume filling, the Nomad II will automatically stop after a few seconds of running.
Operation Instruction: 12V Battery 1) Using the included jumper cables, connect the red clamp to the positive post on the battery. Then connect the black clamp to the negative post on the battery (fig. 1). 1 2) Connect the cables to the compressor by inserting the yellow plug into the outlet on the compressor (fig. 2). 3) Set the desired fill pressure via the dial on the top of the pressure gauge (fig. 3).
Operation Instruction: 12V Battery 8) Once these steps are complete, depress the POWER/RESET button.The LOAD gauge will illuminate and the compressor fans will begin to run (fig. 8). 8 9) Once the fans are running, depress the ON/OFF button to begin filling (fig. 9). Note: You can stop the fill process at any time by depressing the ON/ OFF button. If you do stop the fill for any reason, you MUST bleed the pressure in the line before resuming filling.
Operating the Lights The blue lighting on the underside of your Nomad II will only come on once the POWER/RESET button has been depressed, turning the unit on. 1) Locate the red ON/OFF switch in the middle of the LED light panel on the underside of the unit. 1 2) If you want the LED lights to turn on while the unit is operational, depress the " " symbol on the red switch (fig. 1). 1: LED lights On 3) If you want the LED lights turned off (fig.
Lubricating your Nomad II Compressor Locate the lubrication hole on the left hand side of the unit. Using the included oil applicator bottle, apply 2-3 drops of silicone oil every 5 fills or 1.5 hours of use (whichever comes first). The “LOAD” gauge on the top of the Nomad II can also be used to determine oil application intervals. If the LOAD gauge reaches 28 during operation, it is necessary to apply silicone oil. The Nomad II will automatically shut off if the LOAD gauge exceeds 29.
Purging the Lubrication System Every 20 fills it is important to purge the Nomad II of excess silicone oil and moisture. Once you have completed the 20th fill with your Nomad II, before opening the Pressure Release Valve, locate the Moisture Release Valve on the underside of the unit. Turn the Moisture Release Valve counter-clockwise to purge the system. (fig. 1) ! IMPORTANT 1 AIR AND / OR LIQUID MAY BE RELEASED AT HIGH VELOCITY.
Troubleshooting Issue - Compressor will not start - Resolution - Make sure power converter is plugged into a functional electrical outlet and make sure power converter is properly plugged into the compressor. If using a 12V battery, make sure the jumper cables are properly connected as detailed in the instructions. Issue - Compressor is not building pressure - Resolution - Make sure the moisture release valve and the pressure release valve are closed. They should be hand tightened.
Warranty One Year Limited Warranty Your Air Venturi Compressor is manufactured to the highest possible standards, using quality materials to give a lifetime of service. In the unlikely event that there are any defects in materials or workmanship in the first twelve (12) months after retail purchase, we will repair or replace the defective items under warranty. What is covered? • Replacement Parts and labor. • Transportation charges to consumer for repaired product.
Notes 14 © Air Venturi® 2018 / www.airventuri.
Notes 15 © Air Venturi® 2018 / www.airventuri.
AIR VENTURI® 5135 Naiman Parkway, Cleveland, OH 44139 Ph: 216-292-2570 • fax: 216-373-0086