Owner's Manual
7
4
© Air Venturi 2017 / www.airventuri.com / 216-292-2570
Low-pressure burst
disk replacement
You’ll need the following tools:
• 3/8" box wrench
• 3/8-24-UNF-2B go/no-go gauge
• Inch-pound torque wrench
disk is used on your Air Venturi regula-
tor. Burst disks are required by the
U.S. Dept. of Transportation (DOT)
and Transport Canada (TC).
For your 3000 psi Air Venturi
high-pressure burst disk rated for N2/
HPA storage bottles.
ed burst
disk assembly:
1. Unscrew (turn counterclockwise)
the failed unit and discard it. ese
are not serviceable and have
no further use.
2. Visually inspect the female port for
blow it out. If the port is dam-
aged, do NOT replace the disk.
WARNING:
e correct low-pressure burst disk for your Air Venturi 3000 psi tank is rated
1800 psi. Do not replace it with a disk with any other rating!
7
Contact Air Venturi at 216-220-1180 for OEM replacement parts to
service and rebuild your regulator.
If you aren’t comfortable replacing the burst disk, bring it to a
qualied airsmith or call Air Venturi at 216-220-1180.
Call Air Venturi (216-220-1180)
for assistance or contact a
ed airsmith. We recom-
mend that the female port be
checked with a 3/8-24-UNF-2B
go/no-go gauge (available at in-
dustrial supply stores or www.
mscdirect.com) .
3. Screw in the new replacement
unit. Using an inch-pound torque
wrench, torque it to a minimum of
55 inch-pounds and maximum of 95
inch-pounds.
4. If the burst disk assembly does not
seal at 95 inch-pounds, call Air
Venturi at 216-220-1180 or have it
Serious personal injury or death may result from inproper disk replacment. it’s essential
that you replace failed disks with exact replacements. ASTM unied burst disks have the
pressure identication stamped on the head of the unied disks. Some may have the
pressure identier on the side of the unied disk.
aluminum tank, there’s a 5000 psi
1.8K