Aluminum 13 cu tank Includes regulator Patent numbers: 6,851,447 • 7,059,343 • 7,051,751 Fill pressure: 3,000 psi (200 bar) Output: 1,100 psi +/- 10% (75bar) V2 5/17
Contents Safety system ................................................................................ 3 Fill your tank ................................................................................. 4 Gas types ........................................................................................ 5 Service & rebuild your regulator 6 ............................................. Low-pressure burst disk replacement .................................... 7 Fill check-valve ....................
Safety System ASTM 825-14 NGO thread Removable bonnet Black high-pressure & lowpressure burst disks ll valve (not shown) High-pressure manometer (gauge) ASTM safety vent groove Your Air Venturi regulator is equipped with an ASTM-compliant high-pressure bottle burst disc required by the Department of Transportation (DOT). The regulator also has a lowpressure safety burst disk (stamped 1.8K). The 1.8K psi safety burst disk protects you and your gun in the unlikely event the regulator fails. If the 1.
Fill your tank To fill your aluminum tank, connect the tank’s fill port to the fill source. Fill your aluminum tank using the tank's fill port 4 4 © Air Venturi 2017 / www.airventuri.
Gas types Your Air Venturi tank, regulator and NEVER exceed a pressure rating of 3,000 psi (200 bar). It’s important to keep dirt, oil and regulator. Most regulators fail due to dirt or contamination, so cover the fill nipple when not in use. If you use compressed air, make sure the compressor providing that air is equipped with WORKING and moisture separators. WARNINGS: Use only dry, filtered compressed air or nitrogen in your tank. Use no other gas.
Service & rebuild your regulator If you aren’t comfortable disassembling the regulator, bring it to a qualified airsmith or call Air Venturi at 216-220-1180 WARNING: MAKE SURE THE SYSTEM IS COMPLETELY DEGASSED BY DEPRESSING THE BALL VALVE TO EXHAUST ANY TRAPPED GAS. Reference the parts list on page 15 You’ll need the following tools: • 8-32 threaded screw, 2" to 4" long • 5/64" Allen wrench Do not use tools to remove the piston spring pack, as it may damage the piston.
Low-pressure burst disk replacement If you aren’t comfortable replacing the burst disk, bring it to a qualified airsmith or call Air Venturi at 216-220-1180. WARNING: Serious personal injury or death may result from inproper disk replacment. it’s essential that you replace failed disks with exact replacements. ASTM unified burst disks have the pressure identification stamped on the head of the unified disks. Some may have the pressure identifier on the side of the unified disk.
Fill check-valve If you are not comfortable replacing the fill check-valve, bring it to a qualified airsmith or call Air Venturi at 216-220-1180. MAKE SURE THE SYSTEM IS COMPLETELY DEGASSED BY DEPRESSING THE BALL VALVE TO EXHAUST ANY TRAPPED GAS. Your fill check-valve requires periodic inspection. If it’s leaking or you notice damage on the exterior, replace it. Refer to the parts list on page 15. You’ll need the following tool to ll check-valve: • 7/16" wrench • 1/8-27-NPT go/no-go thread gauge 1.
WARNINGS: Not a toy. Adult supervision required. Misuse or careless use may cause serious injury or death. Use only dry, filtered compressed air or nitrogen in your tank. Don’t use any other gas, including oxygen, which can cause a fire or explosion that may result in serious injury or death. Use diver's silicone grease where lubrication is indicated in this manual.
General maintenance ALWAYS keep the universal fill adapter clean and dry ALWAYS keep the threads of the valve body and cylinder free form oil, dirt and other contaminants. You may wipe these with a clean dry cloth if required. NEVER overfill or have your cylinder filled beyond its rated capacity. Overfilling may result in property damage, personal injury or death. NEVER tamper with or alter the cylinder valve, safety relief device or other cylinder attachments.
Warranty Your Air Venturi aluminum tank and regulator are manufactured to the highest possible standards, using the finest materials to give a lifetime of service. in the unlikely event there are defects in materials or workmanship in the first twelve (12) months after retails purchase, we will repair or replace the defective items under warranty. Note—The warranty will be invalid if: • Any items have been incorrectly disassembled, reassembled or maintained.
YSTEM OR SYSTEM l SHP Belleville springs correct orientation AIR VENTURI REGULATOR SYSTEM NINJA PRO V2 SHP REGULATOR SYSTEM • factory set at 1100 PSI • can be adjusted to 950 PSI with removal of all three internal shims Figure 1b NOTE: THE SHP REGULATOR can only be set at either 1100 PSI or 950 PSI. DO NOT ADD SHIMS. AIR VENTURI REGULATOR ASSEMBLY SHP Belleville springs correct orientation Figure 1b AIR VENTURI REGULATOR ASSEMBLY 5K Burst Disk 5K Burst Disk 12 © Air Venturi 2017 / www.
Notes © Air Venturi 2017 / www.airventuri.
Notes © Air Venturi 2017 / www.airventuri.
Notes © Air Venturi 2017 / www.airventuri.
® AIR VENTURI 5135 Naiman Parkway, Cleveland, OH 44139 216-292-2570 • fax 216-373-0086