Installation Instructions
2. DRILLING THE GUIDE HOLE: Measure the distance
to the ridgeline and to one end of the roof. Transfer
these exterior dimensions to inside the attic. Next,
locate a center position between two rafters (inside
the attic) as near as possible to the outside measure-
ments. Drill a guide hole through the roof from inside
that is equal distance from the two rafters. Place a
marker through the roof for quick identification while
on the roof.
3. CUTTING THE HOLE: Draw a circle 14
1
/
2" in diameter
using the guidehole as the center. A template is provided
on the back of the carton for drawing the circle.
4. CUTTING THE HOLE IN THE ROOF: Using a sabre
saw, cut and remove all roof shingles (and deck) inside
the 14
1
/
2"-diameter circle. Next, cut an extra 1" off the
top half of the hole (shingles only) to allow room for
placing and positioning the flange. Do not cut through
any rafters. Cutting a rafter may cause your roof to sag.
5. SECURING THE BASE: Make sure the base flange
parallels the ridgeline of the roof. The embossed arrow
and word UP should be pointing toward the ridgeline.
Slip the upper half of the flange under the shingles.
Center unit over the hole (as shown above). Attach
flange securely to roof using roofing nails around the
perimeter of the unit (underneath shingles at the top).
A nonhardening caulk can be used as a seal between
the flange and shingles.
6. INSTALLING THE THERMOSTAT: Inside the attic,
separate the thermostat cover from the mounting plate.
Secure the plate to a rafter. See Step 7 to connect the
thermostat.
7. WIRING THE THERMOSTAT: Wire the thermostat
as shown below. Attach your ground wire to the
thermostat box.
POWERCOOL PLUS 15 / POWERCOOL PLUS 12 POWER ATTIC VENTILATORS INSTALLATION INSTRUCTIONS / WARRANTY
WIRING THE THERMOSTAT
YOUR POWER SUPPLY
GROUND SCREW
BLACK
WHITE
CONNECTED AT THE FACTORY–
DO NOT DISCONNECT
14
1
/
2
inches