Model Capacity Dimensions mm Weight Noise
Height Width Depth kg level
5711-3 6 x 1/1GN 715 890 784 120 < 70 dB (A)
5712-3 10 x 1/1GN 941 890 928 170 < 70 dB (A)
5714-3 20 x 1/1GN 1748 890 928 250 < 70 dB (A)
5717-3 20 x 2/1GN 1748 890 1243 340 < 70 dB (A)
1. Technical data
Model Version Rated voltage Control Rated voltage Nominal input Rated Wiring
voltage heating elements heating elements output diagram Nr.
5711-3 VI 3N AC 400V 50Hz 230V 230V 9 000W 9 300W 883 606-3
5711-3 VII 3N AC 400V 50Hz 230V 230V 9 000W 9 300W 884 607-3
5711-3 VIII, X 3N AC 400V 50Hz 230V 230V 9 000W 9 300W 884 608-3
5712-3 VI 3N AC 400V 50Hz 230V 230V 17 000W 17 300W 883 622-3
5712-3 VII 3N AC 400V 50Hz 230V 230V 17 000W 17 300W 883 619-3
5712-3 VIII, X 3N AC 400V 50Hz 230V 230V 17 000W 17 300W 883 620-3
5714-3 VI 3N AC 400V 50Hz 230V 230V 34 000W 34 500W 883 622-3
5714-3 VII 3N AC 400V 50Hz 230V 230V 34 000W 34 500W 883 619-3
5714-3 VIII, X 3N AC 400V 50Hz 230V 230V 34 000W 34 500W 883 620-3
5717-3 VI 3N AC 400V 50Hz 230V 400V 48 000W 48 900W 883 615-3
5717-3 VII 3N AC 400V 50Hz 230V 400V 48 000W 48 900W 884 609-3
5717-3 VIII, X 3N AC 400V 50Hz 230V 400V 48 000W 48 900W 884 617-3