z Select Sensitivity to set the detection sensitivity level. Higher sensitivity will make it
easier to detect and less objects missing, but more misjudgments.
z Select People / Vehicles / Anything as the detected objects.
z Select Calibration (People or Vehicle Object Sizes). The minimum and maximum
boundary of objects can be specified to improve the detection accuracy. The width
and length values must be at least 6 pixels. If any false detection caused by smaller
objects, you can try to increase the minimum size.
z Min. Size of Calibration: The width and length values must be 6 pixels at least. If any
false detection caused by smaller objects, you can try to increase the minimum size.
z Max. Size of Calibration: It has to be larger than the minimum size and half the frame
size is the most.
z Up to 4 zones can be specified when click the Add Zone function. Left click to add the
point and 15 points at most can be used in each zone.
z Select Delete Zone/All to delete the zones.
z Select Enable/Disable to allow the trigger or not.