User`s manual

3 Installation of the Switch
and direct sunlight.
The switch should not be placed near large electric motors or other strong electromagnetic
sources. As a reference, the strength of the electromagnetic field on site should not exceed the
(RFC) standards for IEC 801-3, Level 2(3V/M) field strength.
The air temperature in the location should be within a range of 32 to 122 °F (0 to 55°C).
The relative humidity in the location should not exceed 95% non-condensing humidity.
The distance between the RJ-45 port and the standard network interface should not exceed 100
meters.
Adequate space should be allowed in front of all the ports, so that each port is easily accessible
for cable connections.
Cabling Guide
For 10/100BASE-TX ports
The 24 RJ-45 station ports require Cat. 5 twisted-pair UTP/STP cable for connection. When
configuring within the 10/100BASE-TX cabling architecture, the cable distance should be within
100m.
The following table summarizes the cable requirement for 10/100BASE-TX connection:
10BASE-T
100 ohm Category 3, 4, 5 UTP/STP cable
100BASE-TX
100 ohm Category 5 UTP/STP cable
Auto MDI/MDI-X function
The SNMP-FSH2400RS is equipped with Auto-MDI/MDI-X function, which allows you to use
straight-thru cable even when connecting to another switch/hub. Simply use the straight-through
cable for all types of 10/100BASE-TX connections, either to a PC or to a networking device such as
other hub or switch.
Connection
Specification
10 /100Base-TX
Ports
Interface
RJ-45
Cable to Use
To an end station
Straight-through twisted-pair cable
To a hub/switch
Straight-through twisted-pair cable
Maximum Distance
100 meters
Table 2-2 Cabling type for 10/100BASE-TX
Making your own UTP/STP cable
11
Ether-FSH2400RS Fast Ethernet Switch User’s Manual V1.0