Troubleshooting guide

14. Reinstall the solenoid valve onto the humidifier side, feed the
flexible black water supply tube back through the humidifier
side, reinstall the humidifier side (if removed) onto the
humidifier body and secure in place, reconnect the water
supply to the solenoid valve, replace the humidifier’s front
cover and secure in place, turn back on the water supply, turn
back on the furnace, and turn on the humidifier
15. Test your repair for leaks and repair if necessary.
4
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE
Figure 4.
AB C
Component
Item Description
Parts List/
Humidifier Model
Component
Number
Warranty
Period
Recommended
Maintenance
Humidifier Body 5000/6000 2 Lifetime Inspect yearly, clean with damp cloth.
Humidifier Side Panel 5000/6000 17 Lifetime Inspect yearly, clean with damp cloth.
Front Cover 5000/6000 16 Lifetime Inspect yearly, clean with damp cloth.
Distribution Tray 5000/6000 11 1 Year
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Filter Holder 5000/6000 9 1 Year
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Solenoid Valve 5000/6000 20 1 Year
Replace as required When replacing
replace the orifice fitting (item 21) and inlet
water filter (item 23) as well.
Orifice Fitting 5000/6000 21 N/A
Replace if plugged, dependant on water
condition. When replacing change the inlet
water filter (item 23) as well.
Inlet Water Filter 5000/6000 23 N/A
Replace as required, dependant on water
condition. Good idea to replace with the
evaporator pad (item 10)
Evaporator Pad 5000/6000 10 N/A
Inspect regularly, replace at least yearly,
dependant on water condition.
Bypass tube 5000/6000 8 1 Year Inspect regularly; replace if necessary.
Water Supply Tube 5000/6000 27 1 Year Inspect regularly; replace if necessary.
Water Drainage Tube 5000/6000 4 1 Year Inspect regularly; replace if necessary.
Needle Valve Assembly 5000/6000 15 1 Year Inspect regularly; replace if necessary.
24 Volt Transformer 5000/6000 13 1 Year Inspect regularly; replace if necessary.
Flexible Water Tube 5000/6000 14 1 Year Inspect regularly; replace if necessary.
Drain Insert 5000/6000 3 1 Year
Inspect when replacing evaporator pad,
clean in warm water and mild soap.
Replace if necessary.
Mechanical Humidistat 5000 1
1 year
mechanism,
lifetime on
housing.
Inspect regularly, Clean housing with damp
cloth – Replace mechanism as required
Digital Humidistat 6000 1
1 year
mechanism,
lifetime on
housing.
Inspect regularly, Clean housing with damp
cloth – Replace humidistat electronics as
required