FLOW-THROUGH FURNACE HUMIDIFIER Model 5000/6000 Warranty Maintenance Troubleshooting Guide
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE WARRANTY The manufacturer guarantees the for the period of one year from the date of purchase, the product will be free of defects in workmanship and/or material. As well the manufacturer offers a life time warranty on the flow through humidifier body. During the warranty period, we will replace or repair any defective part at no charge if the product is returned prepaid to our factory.
Model 5000/6000 Flow Through Humidifiers 3 4. The inlet filter is located inside the black orifice fitting. Using a pointy object (i.e. nail), remove the inlet. 6. After the test is complete firmly replace the flexible water supply tube into the nozzle on the top of the distribution tray. 5. The filter should be fairly clean and free of depree, 7. Replace the front and secure with thumb screw. 6. Replace or clean the inlet filter if required.
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE Figure 4. 14. Reinstall the solenoid valve onto the humidifier side, feed the flexible black water supply tube back through the humidifier side, reinstall the humidifier side (if removed) onto the humidifier body and secure in place, reconnect the water supply to the solenoid valve, replace the humidifier’s front cover and secure in place, turn back on the water supply, turn back on the furnace, and turn on the humidifier 15.
Model 5000/6000 Flow Through Humidifiers Component Parts List/ Component Warranty Item Description Humidifier Model Number Period Duct Mount Humidity Sensor Humidisense Electronic Humidifier Control 5 Recommended Maintenance 6000 29 1 year Replace as required. 5000/6000 Not Shown 1 year Replace as required.
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE EFFECTIVE 2003/2004 1 12 13 11 2 14 15 5 10 24 3 16 6 17 9 4 7 18 19 7 8 20 21 22 28 23 24 27 25 26 MODEL 5000 EC ITEM NUMBER *1 * Specify brand DESCRIPTION QTY/UNIT PART NUMBER humidistat 1/per 01A000015 2 flow through body 1/per 010908002 3 drain insert 1/per 010912000 4 drain hose 15 feet/unit 010930002 5 air damper 1/per 01A170930 6 collar 1/per 01A172107 7 6" spring wire clamp 2/per 010938000 8 bypass
Model 5000/6000 Flow Through Humidifiers EFFECTIVE 2003/2004 1 29 12 13 11 2 14 15 5 10 24 3 16 6 17 9 4 7 18 19 7 8 20 21 22 28 23 24 27 25 26 MODEL 6000 DEC * PART NUMBER ITEM NUMBER DESCRIPTION QTY/UNIT *1 digital humidistat assembly 1/per 011138001 2 flow through body 1/per 010908002 3 drain insert 1/per 010912000 4 drain hose 15 feet/unit 010930002 5 air damper 1/per 01A170930 6 collar 1/per 01A172107 7 6" spring wire clamp 2/per 010938000 8 bypa
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE TROUBLE SHOOTING GUIDE MODEL 5000 AND 6000 HUMIDIFIERS water disconnect the water supply to the unit and turn the water back on. Allow the water to flow into a bucket, reconnect the water after test. • Check the amount of water being supplied to the evaporator pad. (Procedure in Maintenance Guide) PROBLEM: NOT ENOUGH HUMIDITY POSSIBLE CAUSE: Humidistat set too low. REMEDY: Turn up the humidistat.
Model 5000/6000 Flow Through Humidifiers REMEDY: • Adjust bypass damper to fully open position. 9 ducting – use hard ducting for any elbows – take the most direct route when ducting. • Furnace filter is dirty and needs replacement. • The bypass tube or humidifier is installed in front of airconditioning coils or is blocked in some other way – move to another location and ensure maximum air flow.
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE • The bypass tube or humidifier is installed in front of airconditioning coils or is blocked in some other way – move to another location and ensure maximum air flow. • The fan delay on your furnace is not set properly and the furnace fan is shutting off too early when the air is still hot. You should discuss with a HVAC professional to have your furnace’s fan cycle adjusted so you are maximizing the heat delivered to your home.
Model 5000/6000 Flow Through Humidifiers POSSIBLE CAUSE: The humidifier is not turning off when the furnace is turning off. REMEDY: See section above for solution. If the unit is running when the furnace is not in heating mode then very little water will be evaporated and most of the water will be going down the drain. POSSIBLE CAUSE: The unit is working properly and the furnace is supplying the proper conditions – just not happy with the water usage.
WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE MODEL 6000 HUMIDIFIERS ONLY PROBLEM: THE DIGITAL HUMIDISTAT KEEPS RESETTING TO THE DEFAULT SETTINGS. POSSIBLE CAUSE: Power source (transformer) is plugged into an outlet which is being shut off or turns off via a switch. REMEDY: Relocate the transformer to an outlet which cannot be turned off – if you have a renovated basement the outlet may have been wired to a switch with out you knowing.